{"title":"Recovery Units","description":"\u003cp\u003eRefrigerant recovery units for safe removal and reclaim of refrigerant from air conditioning and refrigeration systems. A2L-compatible recovery machines for R32 and next-generation refrigerants. Required for F-Gas compliant decommissioning and system repairs. Same-day dispatch from UK stock.\u003c\/p\u003e","products":[{"product_id":"mastercool-twin-turbo-110v-refrigerant-recovery-machine","title":"Mastercool 69300 Twin Turbo Refrigerant Recovery Unit 110V","description":"\u003ch2\u003eMastercool 69300 — TWIN TURBO Refrigerant Recovery System\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAPPROVED FOR ALL AIR CONDITIONING REFRIGERANTS INCLUDING A2L MILDLY FLAMMABLE REFRIGERANTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMastercool's 69300 Twin Turbo Refrigerant Recovery System is built for professionals who require high performance, efficiency, and durability in their refrigerant recovery processes. It is approved for use with all refrigerants, including mildly flammable A2L refrigerants and has recovery rates amongst the highest in the industry, making it the most powerful solution for HVAC and refrigeration recovery applications.\u003c\/p\u003e\n\u003ch2\u003eUnmatched Power, Precision, and Durability for Superior Refrigerant Recovery Performance\u003c\/h2\u003e\n\u003cp\u003eThe enhanced internal structure of Mastercool's Twin Turbo Refrigerant Recovery System allows for maximum recovery capacity whilst at the same time decreasing size and weight. The design of the dual piston oil-less compressor provides maximum recovery efficiency whilst the high-volume cooling fan and condenser ensures optimal cooling efficiency which keeps the compressor working at higher capacities. A safety high pressure cut-off switch automatically stops operation if pressure levels exceed safe limits whilst the purge valve ensures 100% refrigerant removal from the condenser and recovery machine. Encased in a durable, reinforced plastic shell, Mastercool's Twin Turbo Refrigerant Recovery System is engineered to endure challenging work environments, whether for residential, commercial, or industrial tasks, all whilst delivering fast and efficient performance.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety High Pressure Cut-Off Switch:\u003c\/strong\u003e Automatically stops operation if pressure levels exceed safe limits which protects both the user and the equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevolutionary Dual Piston Oil-Less Compressor:\u003c\/strong\u003e Delivers maximum recovery efficiency whilst reducing size and weight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Volume Cooling Fan:\u003c\/strong\u003e Prevents overheating and ensures consistent performance in high-temperature environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLargest Volume Recovery Rate:\u003c\/strong\u003e In the market allowing technicians to handle demanding jobs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with All Refrigerants:\u003c\/strong\u003e Including CFCs, HCFCs, HFCs and A2L mildly flammable refrigerants (R410a, R22, etc) making it ideal for HVAC and refrigeration recovery tasks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable and Portable:\u003c\/strong\u003e Injection moulded high density polyethylene case with built-in bumper guards for enhanced impact resistance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSealed Crank Case:\u003c\/strong\u003e Eliminates refrigerant loss during the recovery process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 69300\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 115V \/ 60Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Power:\u003c\/strong\u003e ½ HP dual piston oil-less compressor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 32 to 122°F (0 to 50°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e High-Density Polyethylene (HDPE) hard plastic case\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Refrigerants:\u003c\/strong\u003e All CFC, HCFC, HFC's and A2L mildly flammable refrigerants\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 12 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSKU:\u003c\/strong\u003e 69300\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHS Code:\u003c\/strong\u003e 84189910\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRecovery Rates\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eR22:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect vapour: up to 0.63 lb\/min (0.29 kg\/min)\u003c\/li\u003e\n\u003cli\u003eDirect liquid: up to 7.56 lb\/min (3.43 kg\/min)\u003c\/li\u003e\n\u003cli\u003ePush pull: up to 18.3 lb\/min (8.30 kg\/min)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eR410A:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect vapour: up to 0.70 lb\/min (0.32 kg\/min)\u003c\/li\u003e\n\u003cli\u003eDirect liquid: up to 7.7 lb\/min (3.49 kg\/min)\u003c\/li\u003e\n\u003cli\u003ePush pull: up to 20.2 lb\/min (9.16 kg\/min)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAlso Available\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/10830601879886\"\u003e69300-2V-UK — TWIN TURBO Dual Voltage Recovery Unit (UK)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/10830601814350\"\u003e69300-220-EU — TWIN TURBO Recovery Unit NF E35-421 (220V)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC refrigerant recovery\u003c\/li\u003e\n\u003cli\u003eCommercial refrigeration service\u003c\/li\u003e\n\u003cli\u003eAutomotive A\/C recovery\u003c\/li\u003e\n\u003cli\u003eResidential A\/C service\u003c\/li\u003e\n\u003cli\u003eHeat pump service\u003c\/li\u003e\n\u003cli\u003eR410A system recovery\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant recovery\u003c\/li\u003e\n\u003cli\u003eHigh-volume recovery operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBenefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighest Recovery Rates:\u003c\/strong\u003e Industry-leading performance for maximum productivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA2L Approved:\u003c\/strong\u003e Ready for modern mildly flammable refrigerants\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil-Less Compressor:\u003c\/strong\u003e No oil contamination, reduced maintenance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Protection:\u003c\/strong\u003e High pressure cut-off prevents equipment damage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Cooling:\u003c\/strong\u003e High-volume fan maintains optimal operating temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e HDPE case with bumper guards for job site protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSealed Crank Case:\u003c\/strong\u003e Zero refrigerant loss during recovery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Maximum power in reduced size and weight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Quality:\u003c\/strong\u003e Built for daily commercial use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePerfect For\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC\/R contractors and installers\u003c\/li\u003e\n\u003cli\u003eCommercial refrigeration technicians\u003c\/li\u003e\n\u003cli\u003eAutomotive A\/C specialists\u003c\/li\u003e\n\u003cli\u003eWorkshop and service centres\u003c\/li\u003e\n\u003cli\u003eMobile service operations\u003c\/li\u003e\n\u003cli\u003eFleet maintenance facilities\u003c\/li\u003e\n\u003cli\u003eHigh-volume recovery operations\u003c\/li\u003e\n\u003cli\u003eTechnicians working with A2L refrigerants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy TWIN TURBO?\u003c\/h2\u003e\n\u003cp\u003eThe TWIN TURBO designation refers to the revolutionary dual piston oil-less compressor design that delivers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Recovery Efficiency:\u003c\/strong\u003e Dual pistons provide superior performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Size and Weight:\u003c\/strong\u003e More power in a compact package\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil-Less Operation:\u003c\/strong\u003e No oil contamination of recovered refrigerant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLonger Service Life:\u003c\/strong\u003e Less wear and tear than traditional compressors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConsistent Performance:\u003c\/strong\u003e Reliable operation in demanding conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eA2L Refrigerant Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe 69300 is approved for A2L mildly flammable refrigerants, making it future-ready for modern HVAC systems:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eR32:\u003c\/strong\u003e Common in residential A\/C systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR454B:\u003c\/strong\u003e R410A replacement refrigerant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR1234yf:\u003c\/strong\u003e Automotive A\/C refrigerant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther A2L Refrigerants:\u003c\/strong\u003e Approved for all mildly flammable refrigerants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOperation\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eConnect recovery hoses to system and recovery cylinder\u003c\/li\u003e\n\u003cli\u003eEnsure recovery cylinder is on scale (if weighing)\u003c\/li\u003e\n\u003cli\u003ePower on 69300 recovery unit\u003c\/li\u003e\n\u003cli\u003eOpen valves and begin recovery\u003c\/li\u003e\n\u003cli\u003eHigh-volume cooling fan maintains optimal temperature\u003c\/li\u003e\n\u003cli\u003eMonitor recovery progress\u003c\/li\u003e\n\u003cli\u003eSafety cut-off protects against over-pressure\u003c\/li\u003e\n\u003cli\u003eWhen complete, use purge valve to remove 100% of refrigerant\u003c\/li\u003e\n\u003cli\u003eClose valves and power off unit\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eMaintenance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Fan:\u003c\/strong\u003e Keep fan and vents clean for optimal cooling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePurge Valve:\u003c\/strong\u003e Use after each recovery to ensure complete refrigerant removal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase:\u003c\/strong\u003e Clean HDPE case regularly, inspect bumper guards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e Check hose connections for leaks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage:\u003c\/strong\u003e Store in clean, dry environment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection:\u003c\/strong\u003e Regularly inspect for damage or wear\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSafety Guidelines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAlways wear safety glasses when recovering refrigerant\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation\u003c\/li\u003e\n\u003cli\u003eFollow proper refrigerant handling procedures\u003c\/li\u003e\n\u003cli\u003eDo not exceed operating temperature range (32-122°F)\u003c\/li\u003e\n\u003cli\u003eAllow high pressure cut-off to function - do not bypass\u003c\/li\u003e\n\u003cli\u003eUse appropriate recovery cylinder for refrigerant type\u003c\/li\u003e\n\u003cli\u003eFollow A2L refrigerant safety protocols when applicable\u003c\/li\u003e\n\u003cli\u003eKeep unit away from ignition sources when recovering A2L refrigerants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Quality:\u003c\/strong\u003e Mastercool refrigerant recovery systems are built to professional standards for reliable, high-performance refrigerant recovery in demanding HVAC\/R service environments. The 69300 TWIN TURBO features revolutionary dual piston oil-less compressor technology, industry-leading recovery rates, A2L refrigerant approval, and durable HDPE construction for professional recovery operations. 115V \/ 60Hz.\u003c\/p\u003e","brand":"Mastercool","offers":[{"title":"Default Title","offer_id":57030052020601,"sku":"69300","price":1176.42,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/0158\/3481\/files\/Mastercool-Twin-Turbo-110v-Refrigerant-Recovery-Machine-Ryan-Air-Conditioning-Spares-68967772651895.jpg?v=1775894679"}],"url":"https:\/\/www.airconspares.com\/collections\/recovery-units.oembed","provider":"Airconspares.com","version":"1.0","type":"link"}