{"product_id":"kd-cellar-star-pap015mr1-packaged-cellar-cooling-system","title":"KD Cellar Star PAP015MR1 Packaged Cellar Cooling System","description":"\u003ch2\u003eKD Cellar Star PAP015MR1 Packaged Cellar Cooling System\u003c\/h2\u003e\n\u003cp\u003eThe KD Cellar Star PAP015MR1 is a complete packaged cellar cooling system from SRW\/Thermofrost (JE Hall), designed to maintain cask and keg beer at the correct serving temperature in pub and bar cellars. Supplied as a matched pair — an indoor evaporator unit and an outdoor condensing unit — the system uses the lower-GWP R449A refrigerant and is sized for cellars of up to 45 m³ above ground (55 m³ below ground).\u003c\/p\u003e\n\u003cp\u003eSupplied as a complete indoor\/outdoor pair, ready for installation and commissioning by a qualified refrigeration engineer.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete packaged system: indoor evaporator + outdoor condensing unit\u003c\/li\u003e\n\u003cli\u003eCools cellars up to 45 m³ above ground \/ 55 m³ below ground\u003c\/li\u003e\n\u003cli\u003eR449A refrigerant — lower GWP than R404A\u003c\/li\u003e\n\u003cli\u003eSingle phase 230V power supply\u003c\/li\u003e\n\u003cli\u003eMaintains cellar temperature range of 4°C to 16°C\u003c\/li\u003e\n\u003cli\u003eNominal cooling capacity approximately 3.68 kW\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePurpose-built for cellar cooling\u003c\/strong\u003e — maintains consistent cask and keg beer temperature for correct serving condition and reduced wastage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLower environmental impact\u003c\/strong\u003e — R449A refrigerant offers a significantly lower global warming potential than legacy R404A systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatched pair, simple specification\u003c\/strong\u003e — indoor and outdoor units are supplied as a correctly matched system, removing guesswork over compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable single-phase supply\u003c\/strong\u003e — straightforward electrical connection suitable for the vast majority of pub and bar installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSuitable Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePub and bar cellars storing cask and keg beer\u003c\/li\u003e\n\u003cli\u003eBelow-ground and above-ground cellar rooms up to 45–55 m³\u003c\/li\u003e\n\u003cli\u003eNew cellar cooling installations and system replacements\u003c\/li\u003e\n\u003cli\u003eLicensed premises requiring consistent cellar temperature control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePAP015MR1 (KD Cellar Star)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Evaporator Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKNCE015M1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Condensing Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKNCU015M1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Cooling Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.68 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Cellar Volume (Above Ground)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Cellar Volume (Below Ground)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR449A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFactory Pre-Charge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Refrigerant Charge Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51.7 g\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V, single phase, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Load Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocked Rotor Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Unit Dimensions W × H × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e840 × 590 × 327 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor Unit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Unit Dimensions W × H × D\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e822 × 615 × 342 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor Unit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Level (Indoor \/ Outdoor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 dBA \/ 29 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" liquid \/ 1\/2\" suction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Pipe Run\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 m (length), 5 m (rise)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4°C to 16°C (cellar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRoom Size Guide\u003c\/h3\u003e\n\u003cp\u003eAs a general guide, the PAP015MR1 is suitable for cellar rooms of up to \u003cstrong\u003e45 m³\u003c\/strong\u003e above ground or \u003cstrong\u003e55 m³\u003c\/strong\u003e below ground, subject to insulation standard, door frequency, pipe run length and ambient conditions. For larger cellars or unusual layouts, a qualified refrigeration engineer should confirm sizing before ordering.\u003c\/p\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKNCE015M1 indoor evaporator unit\u003c\/li\u003e\n\u003cli\u003eKNCU015M1 outdoor condensing unit\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003ePipework, controls wiring and installation materials are sold separately.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eRecommended Installation Accessories\u003c\/h3\u003e\n\u003cp\u003eTo complete the installation, your engineer will typically require the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigeration-grade copper pipework\u003c\/strong\u003e — in the correct diameter for this system (3\/8\" liquid \/ 1\/2\" suction)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe insulation\u003c\/strong\u003e — closed-cell insulation for the full pipe run to prevent condensation and maintain efficiency\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor unit mounting feet or bracket\u003c\/strong\u003e — suitable for the 51kg outdoor unit weight\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal isolator switch\u003c\/strong\u003e — required by Part P of the Building Regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterconnecting control cable\u003c\/strong\u003e — sized to the installation manual, to connect indoor and outdoor units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAre the indoor and outdoor units sold together?\u003c\/strong\u003e\u003cbr\u003eYes. This listing is for the complete matched pair — KNCE015M1 indoor evaporator and KNCU015M1 outdoor condensing unit — supplied and priced as one system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this system include installation?\u003c\/strong\u003e\u003cbr\u003eNo. This listing is for the equipment only. Installation and commissioning must be carried out by a qualified F-Gas certified refrigeration engineer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat refrigerant does this system use?\u003c\/strong\u003e\u003cbr\u003eR449A, a lower global warming potential refrigerant. Handling requires F-Gas certification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat size cellar is this suitable for?\u003c\/strong\u003e\u003cbr\u003eAs a general guide, up to 45 m³ above ground or 55 m³ below ground. A site survey is recommended to confirm suitability for larger or non-standard cellars.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat temperature range does this system maintain?\u003c\/strong\u003e\u003cbr\u003eThe system is designed to hold cellar temperatures between 4°C and 16°C, suitable for cask and keg beer storage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat pipe sizes does this system require?\u003c\/strong\u003e\u003cbr\u003e3\/8\" liquid line and 1\/2\" suction line, in refrigeration-grade copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum pipe run length?\u003c\/strong\u003e\u003cbr\u003e25 metres in length, with a maximum vertical rise of 5 metres. Additional refrigerant charge is required beyond the factory pre-charge at 51.7 g\/m.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply does this system need?\u003c\/strong\u003e\u003cbr\u003e230V single phase, 50Hz, with a 20A fuse rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs a local isolator required?\u003c\/strong\u003e\u003cbr\u003eYes. A local isolator switch is required by Part P of the Building Regulations and should be installed by a qualified electrician.\u003c\/p\u003e\n\u003ch3\u003eProfessional Installation Required\u003c\/h3\u003e\n\u003cp\u003eThis cellar cooling system must be installed and commissioned by an appropriately F-Gas certified refrigeration engineer. Installation, pipework, electrical connection and commissioning are not included in this listing unless separately agreed in writing. Handling of R449A refrigerant requires appropriate F-Gas certification under UK F-Gas Regulations.\u003c\/p\u003e\n\u003ch3\u003eManufacturer Resources\u003c\/h3\u003e\n\u003cp\u003eFor full manufacturer documentation, visit the \u003ca href=\"https:\/\/www.srw.co.uk\/product\/pap015mr1-kd-cellar-star-cooler-r449a-max-45m3\/\"\u003eofficial SRW\/JE Hall KD Cellar Star product page\u003c\/a\u003e.\u003c\/p\u003e\n","brand":"SRW","offers":[{"title":"Default Title","offer_id":64737833124217,"sku":"KNCE015M1+KNCU015M1","price":2448.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/0158\/3481\/files\/KD-Cellar-Star-Cellar-Cooling-system_png.png?v=1790752697","url":"https:\/\/www.airconspares.com\/de\/products\/kd-cellar-star-pap015mr1-packaged-cellar-cooling-system","provider":"Airconspares.com","version":"1.0","type":"link"}