{"product_id":"90063-2v-220svb","title":"Mastercool 90063 3 CFM 2-Stage Vacuum Pump with Solenoid Valve 220V for HVAC","description":"\u003ch1\u003eMastercool 90063-2V-220SVB — 85 L\/min Vacuum Pump with Solenoid Valve\u003c\/h1\u003e\n\u003cp\u003eProfessional 2-stage vacuum pump with integrated solenoid valve and vacuum gauge assembly. Delivers 85 litres per minute at 60Hz (71 L\/min at 50Hz) evacuation capacity for efficient HVAC\/R system service. The built-in solenoid valve provides automated pump protection and enables vacuum leak testing, achieving an ultimate vacuum of 15 microns under optimal conditions.\u003c\/p\u003e\n\u003ch2\u003eKey Features:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e85 L\/min Displacement\u003c\/strong\u003e – 85 L\/min at 60Hz, 71 L\/min at 50Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Stage Design\u003c\/strong\u003e – Achieves 15 microns ultimate vacuum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Solenoid Valve\u003c\/strong\u003e – Automated pump protection and control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum Gauge Included\u003c\/strong\u003e – Monitor vacuum levels during evacuation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e220V 50\/60Hz Operation\u003c\/strong\u003e – Flexible frequency operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\/3 HP Motor\u003c\/strong\u003e – 1440 RPM pump speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLightweight Design\u003c\/strong\u003e – Only 7.37 kg (16.2 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShuko Power Cord\u003c\/strong\u003e – 220V European-style plug included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: 90063-2V-220SVB\u003c\/li\u003e\n\u003cli\u003eType: 2-stage vacuum pump with solenoid valve\u003c\/li\u003e\n\u003cli\u003eStages: 2-stage\u003c\/li\u003e\n\u003cli\u003eFree Air Displacement: 85 L\/min (60Hz), 71 L\/min (50Hz)\u003c\/li\u003e\n\u003cli\u003eUltimate Vacuum: 15 microns*\u003c\/li\u003e\n\u003cli\u003eMotor Power: 1\/3 HP\u003c\/li\u003e\n\u003cli\u003ePump Speed: 1440 RPM\u003c\/li\u003e\n\u003cli\u003eVoltage: 220V\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePower Cord: 220V cable (Shuko plug)\u003c\/li\u003e\n\u003cli\u003eWeight: 7.37 kg (16.2 lbs)\u003c\/li\u003e\n\u003cli\u003eSolenoid Valve: Integrated\u003c\/li\u003e\n\u003cli\u003eVacuum Gauge: Included\u003c\/li\u003e\n\u003cli\u003eApplication: HVAC\/R system evacuation\u003c\/li\u003e\n\u003cli\u003eSKU: 90063-2V-220SVB\u003c\/li\u003e\n\u003cli\u003eBarcode: 700376117387\u003c\/li\u003e\n\u003cli\u003eHS Code: 84148080\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* PLEASE NOTE: The micron readings on all vacuum pumps represent optimal laboratory conditions. Field conditions may vary from these readings.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003eSolenoid Valve Benefits:\u003c\/h2\u003e\n\u003cp\u003eThe integrated solenoid valve provides critical pump protection by automatically isolating the pump from the system. This prevents system contamination from entering the pump oil and enables vacuum leak testing by holding vacuum whilst monitoring gauge readings. The solenoid valve can be controlled manually or connected to automated evacuation systems for hands-free operation.\u003c\/p\u003e\n\u003ch2\u003e2-Stage Vacuum Technology:\u003c\/h2\u003e\n\u003cp\u003eThe 2-stage design achieves deeper vacuum levels than single-stage pumps, enabling faster, more complete evacuation of HVAC\/R systems. The first stage removes the bulk of air and moisture, whilst the second stage pulls down to 15 microns ultimate vacuum – essential for removing trace moisture and ensuring system integrity.\u003c\/p\u003e\n\u003ch2\u003eApplications:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC\/R system evacuation and dehydration\u003c\/li\u003e\n\u003cli\u003eRefrigeration installation and service\u003c\/li\u003e\n\u003cli\u003eAir conditioning system commissioning\u003c\/li\u003e\n\u003cli\u003eVacuum leak testing with integrated gauge\u003c\/li\u003e\n\u003cli\u003eMini-split system installation\u003c\/li\u003e\n\u003cli\u003eCommercial refrigeration service\u003c\/li\u003e\n\u003cli\u003eWorkshop and mobile service applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Vacuum Pumps:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/mastercool-90063-2v-220bl-dual-voltage-vacuum-pump-2-stage-3-cfm-90-l-min\"\u003e90063-2V-220BL — Dual Voltage 2-Stage 90 L\/min (3 CFM)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/mastercool-90063-2v-220svbl-black-series-2-stage-vacuum-pump-70-lit-min-with-solenoid-valve\"\u003e90063-2V-220SVBL — Black Series 71 L\/min with Solenoid Valve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/mastercool-90063-2v-220-bl-black-series-2-stage-vacuum-pump-70-lit-min-50hz-1-3-hp\"\u003e90063-2V-220-BL — Black Series 71 L\/min 1\/3 HP\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVacuum Pump Oil:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/mastercool-90010-6-box-of-6-10oz-295ml-btls-of-vacuum-pump-oil-90063\"\u003e90010-6 — Box of 6 x 10oz Vacuum Pump Oil\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVacuum Measurement:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/mastercool-98063-bt-electronic-vacuum-gauge-w-bluetooth\"\u003e98063-BT — Electronic Vacuum Gauge with Bluetooth\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCharging Stations (with integrated vacuum pumps):\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/mastercool-91584-2v-220-dual-voltage-portable-electronic-charging-station-4-way-71-l-min-220v-110v\"\u003e91584-2V-220 — Dual Voltage 4-Way Charging Station 71 L\/min\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/mastercool-91583-2v-220-dual-voltage-portable-electronic-charging-station-2-way-71-l-min-220v-110v\"\u003e91583-2V-220 — Dual Voltage 2-Way Charging Station 71 L\/min\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose This Vacuum Pump?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Capacity\u003c\/strong\u003e – 85 L\/min at 60Hz for fast evacuation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeep Vacuum\u003c\/strong\u003e – 15 microns ultimate vacuum removes trace moisture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Solenoid\u003c\/strong\u003e – Pump protection and leak testing in one unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLightweight\u003c\/strong\u003e – Only 7.37 kg for easy portability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Frequency\u003c\/strong\u003e – 50\/60Hz operation for international use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Grade\u003c\/strong\u003e – Mastercool reliability for daily workshop use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOperating Instructions:\u003c\/h2\u003e\n\u003cp\u003eEnsure pump oil is at correct level before use. Connect vacuum hose to pump inlet. Start pump and allow to run briefly before connecting to system. Connect to HVAC\/R system and evacuate to desired vacuum level (typically 500 microns or below for field conditions). Use integrated solenoid valve to isolate pump and perform vacuum leak test. Monitor gauge for vacuum decay.\u003c\/p\u003e\n\u003ch2\u003eMaintenance:\u003c\/h2\u003e\n\u003cp\u003eChange pump oil regularly (after every 8-10 hours of use or when contaminated). Check oil level before each use. Keep air intake filter clean. Inspect hoses and connections for leaks. Store in clean, dry location. Never run pump without oil or with contaminated oil.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional 2-stage vacuum pump\u003c\/strong\u003e with integrated solenoid valve and gauge. 85 L\/min at 60Hz (71 L\/min at 50Hz), 15 microns ultimate vacuum, 220V 50\/60Hz operation. Perfect for HVAC\/R evacuation and leak testing.\u003c\/p\u003e","brand":"Mastercool","offers":[{"title":"Default Title","offer_id":57164766183801,"sku":"90063-2V-220SVB","price":557.61,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/0158\/3481\/files\/90063-2V-220SVB_web.jpg?v=1777446817","url":"https:\/\/www.airconspares.com\/products\/90063-2v-220svb","provider":"Airconspares.com","version":"1.0","type":"link"}