Sauermann Si-50 Peristaltic Condensate Pump | SI50CE01UN23
The Sauermann Si-50 is a peristaltic condensate pump designed for all types of air conditioning units up to 8 kW: wall units, air conditioning cabinets, ceiling units, and ducted units. Controlled by the air conditioner compressor power signal (cooling signal), it activates when the compressor runs and continues operating for 4 minutes after the compressor stops to clear residual condensate.
⚠️ Important: The Si-50 is not compatible with reversible or inverter systems as it must not be used in continuous operation. For inverter or reversible systems, see the Sauermann Si-52.
Key Features
- Peristaltic pump — quiet, vibration-free, self-priming operation
- Compressor live signal detection — wired directly to compressor line
- Runs 4 minutes after compressor stops — clears residual condensate
- 12 m maximum discharge head | 2 m maximum suction head
- 6 L/h constant flow rate (regardless of discharge or suction head)
- IP55 protection — suitable for unventilated areas
- ≤30 dBA — quiet, vibration-free operation
- Thick, reinforced tube for longer service life
- Resistance to contaminated condensate (particles and chemicals)
- Easy-open front panel — tool-free tube replacement
- Glass fuse replaceable in one step (standard 5×20 cartridge)
- Compact: L85 × W108 × H122 mm
- CE & UKCA certified | RoHS & WEEE compliant | Made in France
Technical Specifications
| Part Number | SI50CE01UN23 |
| Max Flow Rate | 6 L/h (constant) |
| Max Suction Head | 2 m |
| Max Discharge Head | 12 m |
| Detection Type | Compressor live signal (cooling signal) |
| Run-on Time | 4 minutes after compressor stops |
| Mains Supply | 230 V~ 50/60 Hz — 8 W |
| Insulation Class | Double insulation |
| Sound Level | ≤30 dBA at 1 m |
| IP Rating | IP55 |
| Pump Dimensions | L85 × W108 × H122 mm |
| Operating & Storage Temp | +2°C to +45°C |
| Weight (with packaging) | 0.8 kg |
| Safety Standards | CE & UKCA |
| Country of Origin | France |
Kit Contents
- Peristaltic pump Si-50
- Cable 1.7 m including 2 wires for power supply (P & N) + compressor line wire
- Easy 2-screw sliding plastic bracket
- Ø15 mm to Ø6 mm adaptor + sleeve (ACC00927)
Applications
- Wall-mounted split AC units up to 8 kW
- Air conditioning cabinets
- Ceiling suspended units
- Computer room air conditioning
- Ducted systems
- Ideal for dusty or chemical environments (bakeries, hairdressers, hotels)
- Hotels — maintenance possible without accessing rooms
Si-50 vs Si-51 vs Si-52 — Which Do I Need?
| Model | Detection | Inverter/Reversible? |
| Si-50 | Compressor live signal | ❌ Not compatible |
| Si-51 | Thermal probes (temp differential) | ❌ Not compatible |
| Si-52 | Float switch | ✅ Compatible |
PE-Series Spare-Part Compatibility
Use the spare parts specified for the pump family: PE5001 and PE5002 are specified for the PE-5000 / PE-5100 / PE-5200 range, while ACC00954 and ACC00953 are specified for the Si-50 / Si-51 / Si-52 range.
Compatible Accessories
- ACC00954 — Replacement head for Si-50, Si-51, Si-52
- ACC00953 — Replacement hose for Si-50, Si-51, Si-52
- ACC00927 — Multi-diameter reducing adaptor (Ø15 mm to Ø6 mm)
- ACC20005 — 6× self-sealing fittings for Ø6 mm (1/4") hose
- ACC00909 — Clear PVC hose Ø6 mm (5m)
- ACC00910 — Clear PVC hose Ø6 mm (50m)
- Browse all Condensate Pump Accessories
Also in the Sauermann Peristaltic Range
- Sauermann Si-51 — thermal probe detection, not for inverter/reversible
- Sauermann Si-52 — float switch detection, compatible with inverter/reversible
Frequently Asked Questions
- How does the Si-50 know when to run?
- The Si-50 is wired directly to the air conditioner compressor line. It activates when the compressor runs and continues for 4 minutes after the compressor stops to clear any remaining condensate.
- Can the Si-50 be used with inverter or reversible AC systems?
- No. The Si-50 must not be used in continuous operation and is incompatible with reversible and inverter systems. For these systems, use the Sauermann Si-52 instead.
- What is the difference between the Si-50, Si-51, and Si-52?
- The Si-50 uses compressor live signal detection. The Si-51 uses thermal probes (temperature differential). The Si-52 uses a float switch and is the only model compatible with inverter and reversible systems.
- Can I use PE5000 spare parts (PE5001 head, PE5002 tube) on the Si-50?
- No. PE series spare parts are not compatible with the Si-50/51/52. Use ACC00954 (replacement head) and ACC00953 (replacement hose) for SI series servicing.
- Does the Si-50 work on UK 230 V supply?
- Yes. The Si-50 runs on 230 V~ 50/60 Hz standard UK mains supply.