Heat pump enquiries are rising: get defrost and condensate drainage right this winter

Demand for heat pumps is picking up again. PAD Magazine reported on 13 November 2026 that Octopus Energy saw heat pump enquiries rise by 58% in October, the highest level since March. The same report quotes government figures showing 9,738 Boiler Upgrade Scheme (BUS) applications in September 2026, compared with 4,089 a year earlier. On 5 November the Department for Energy Security and Net Zero also gave Ofgem approval to over-allocate BUS vouchers because applications have stayed high.

We covered the coming VAT change in our Knowledge Hub last week. This post looks at a practical point for the installs going in now.

For installers, more enquiries in November means more systems going in just as the weather turns cold. One detail that causes a lot of winter call-backs is drainage: where the water from the outdoor unit actually goes.

Why winter drainage matters

When an air source heat pump, or an air conditioning system running in heating mode, is working hard in cold weather, the outdoor coil collects moisture and frost. The unit melts it off during defrost cycles, and that water has to drain away freely. If it can't, it can freeze in the base of the unit, build up as ice underneath, or run across a path and leave a slip hazard by the back door.

Plan the drainage at survey stage

  • Lift the unit. Mount the outdoor unit on suitable feet, a stand or wall brackets so it sits clear of the ground, standing water and drifting snow, and so defrost water can fall away from the coil.
  • Know where the water goes. Route defrost water to a gully, drain or soakaway rather than onto a patio, path or driveway.
  • Keep outdoor drain runs short. Long, shallow runs of drain hose outside are prone to freezing. Keep falls positive and runs as short as you can.
  • Follow the manufacturer's manual. Check the installation manual for the drain connections, clearances and any base heater or cold-climate options for the model you are fitting. For Daikin units, use the Daikin installation documentation for that model.

Indoor condensate on air-to-air systems

Many customers now use split air conditioning for heating in winter and cooling in summer, so the indoor unit's condensate route has to work all year. Where a gravity fall isn't possible, a correctly sized condensate pump and a tidy drain hose run will save a return visit when the cooling season comes round. Neat trunking keeps pipe, cable and drain together on the wall.

Insulate the pipework properly

Refrigerant pipework on the outside wall should be fully insulated, with joints sealed and the insulation protected from the weather. Our pipework insulation range covers the common sizes for split and heat pump installs.

Get stock sorted before the rush

If enquiries keep rising through the winter, it pays to have mounting kit, drainage parts and insulation on the van before you need them. You can browse our Daikin range alongside the installation materials you'll need to finish the job.

Need a hand choosing parts for a job? Call the RACS team on 0161 775 1190, Monday to Friday, 9am–4pm.