Sauermann Si-51 peristaltic condensate pump with thermal probe detection

Sauermann Si-51 Peristaltic Condensate Pump – Thermal Probe, 6 L/h, 12 m Head

£173.88 Inc VAT £144.90 Ex VAT
Skip to product information
Sauermann Si-51 peristaltic condensate pump with thermal probe detection

Sauermann Si-51 Peristaltic Condensate Pump – Thermal Probe, 6 L/h, 12 m Head

SI-51
£173.88 Inc VAT £144.90 Ex VAT
Back order – expected to dispatch by Wed 18 Nov (usually 5–10 working days)

Can also use In stock now, ready to dispatch

Sauermann PE-5100 Peristaltic Condensate Pump – Thermal Probe, 6 L/h, 12 m Head

£156.82 inc VAT · £130.68 ex VAT

Same thermal-probe peristaltic, 6 L/h, 12 m

Sauermann Si-51 Peristaltic Condensate Pump | SI51CE01UN23

The Sauermann Si-51 is a peristaltic condensate pump designed for air-conditioning units up to 8 kW. It uses two thermal probes (temperature differential detection) to activate automatically when the air conditioner turns on, with no float switch required.

⚠️ Important: The Si-51 is not compatible with reversible or inverter systems as it must not be used in continuous operation. For inverter or reversible systems, see the Sauermann Si-52.

Key Features

  • Peristaltic pump — quiet, vibration-free, self-priming operation
  • Temperature differential detection — 2 thermal probes, activates at ≥6°C differential
  • Runs 4 minutes after temperature differential falls below 6°C
  • 12 m maximum discharge head | 2 m maximum suction head
  • 6 L/h constant flow rate (regardless of discharge or suction head)
  • IP55 protection — suitable for unventilated areas
  • ≤30 dBA — ultra-quiet operation
  • Easy-open front panel — tool-free tube replacement
  • Glass fuse replaceable in one step (standard 5×20 cartridge)
  • Compact: L85 × W108 × H122 mm
  • CE & UKCA certified | RoHS & WEEE compliant | Made in France

Technical Specifications

Part Number SI51CE01UN23
Max Flow Rate 6 L/h (constant)
Max Suction Head 2 m
Max Discharge Head 12 m
Detection Type Temperature differential — 2 thermal probes
Activation Temp diff ≥6°C ON | Runs 4 min after <6°C
Mains Supply 230 V~ 50/60 Hz — 8 W
Sound Level ≤30 dBA
IP Rating IP55
Pump Dimensions L85 × W108 × H122 mm
Operating & Storage Temp +2°C to +45°C
Weight (with packaging) 0.95 kg
Safety Standards CE & UKCA
Country of Origin France

Kit Contents

  • Peristaltic pump Si-51
  • 1.7 m cable including 2 wires for power supply (P & N)
  • 2 thermal probes with 3.5 m cable (red cap = ambient air, blue cap = fresh air)
  • Easy 2-screw sliding plastic bracket
  • Ø15 mm to Ø6 mm adaptor + sleeve (ACC00927)

Applications

  • Wall-mounted split AC units up to 8 kW
  • Ceiling suspended units
  • Computer room air conditioning
  • Ducted systems
  • Ideal for dusty or chemical environments (bakeries, hairdressers, hotels)

Si-50 vs Si-51 vs Si-52 — Which Do I Need?

Model Detection Inverter/Reversible?
Si-50 Compressor live signal ❌ Not compatible
Si-51 Thermal probes (temp differential) ❌ Not compatible
Si-52 Float switch ✅ Compatible

PE-Series Spare-Part Compatibility

Use the spare parts specified for the pump family: PE5001 and PE5002 are for the PE-5000 / PE-5100 / PE-5200 range, while ACC00954 and ACC00953 are for the Si-50 / Si-51 / Si-52 range.

Compatible Accessories

  • ACC00954 — Replacement head for Si-50, Si-51, Si-52
  • ACC00953 — Replacement hose for Si-50, Si-51, Si-52
  • ACC00927 — Multi-diameter reducing adaptor (Ø15 mm to Ø6 mm)
  • ACC00919 — 6× self-sealing fittings for Ø6 mm (1/4") hose
  • ACC00909 — Clear PVC hose Ø6 mm (5m)
  • ACC00910 — Clear PVC hose Ø6 mm (50m)
  • Browse all Condensate Pump Accessories

Also in the Sauermann Peristaltic Range

  • Sauermann Si-50 — compressor signal detection, not for inverter/reversible
  • Sauermann Si-52 — float switch detection, compatible with inverter/reversible

Frequently Asked Questions

Can I use PE-5100 spare parts (tubes, heads) on the Si-51?
No. The replacement heads (ACC00954) and hoses (ACC00953) for the Si-50/51/52 are not backward-compatible with the PE series. Use the PE-series replacement parts specified for the PE-5100, or the Si-series parts specified for the Si-51.
Can the Si-51 be used with inverter or reversible AC systems?
No. The Si-51 must not be used in continuous operation and is incompatible with reversible and inverter systems. Use the Si-52 instead.
What is the difference between the Si-51 and the Si-50?
The Si-50 uses compressor live signal detection. The Si-51 uses thermal probes (temperature differential) and activates automatically based on temperature change rather than a wired compressor signal.
Does the Si-51 work on UK 230 V supply?
Yes. The Si-51 runs on 230 V~ 50/60 Hz standard UK mains supply.