Skills have been in the news this month. Cooling Post reported on 13 November 2026 that IOR Scotland named Aidan Hamilton of Carters its Apprentice of the Year, with Ben Pollard of East Air Conditioning second and Kian Ferns of TRS third. Congratulations to all three.
Meanwhile, a government update published by Installer on 5 November confirmed that Boiler Upgrade Scheme grant levels are unchanged after the Budget, and that the Heat Training Grant offers up to £500 towards approved heat pump training for eligible heating engineers. Check eligibility on GOV.UK before booking a course.
With heat pump enquiries rising, many firms are bringing on apprentices or retraining heating engineers. Training covers the theory. The right kit is what lets new engineers put it into practice safely.
Why A2L and A3 refrigerants change the tool list
Most new split systems now use R32, an A2L (mildly flammable) refrigerant, and many monobloc heat pumps use R290 (propane), an A3 refrigerant. Tools that might create a spark, such as vacuum pumps and recovery machines, need to be suitable for these gases. Older kit bought for R410A may not be.
A starter list for A2L and A3 work
- Spark-proof vacuum pump. Look for a pump rated for A2L/A3 refrigerants. See our vacuum pumps.
- Recovery machine rated for the refrigerant. A2L and A3 recovery needs suitable equipment. See recovery machines.
- Nitrogen kit for pressure testing. A regulator and test rig suited to the pressures involved. See nitrogen equipment.
- Leak detector that picks up the gas you work with. See leak detection.
- Gauges and hoses. A digital manifold and hoses suited to the refrigerant. See gauges and manifolds.
Our A2L installation and commissioning tools collection brings these together in one place, and the R32 tools and R290 tools pages help you match kit to the refrigerant.
Good habits from the first job
The tools only help if they are used well. Habits worth building early with any new engineer:
- Check that every tool on the job is suitable for the refrigerant in the system, not just the last one you worked on.
- Pressure test with oxygen-free nitrogen and record the results.
- Evacuate properly and check the vacuum holds before charging.
- Keep ignition sources away from the work area when working with flammable refrigerants, and follow the manufacturer's instructions.
- Keep F-gas records up to date.
Pairing an apprentice with an experienced engineer on real jobs, with the right kit to hand, is still one of the best ways to build confidence.
Kit an apprentice out properly
A good first tool kit is an investment in the engineer as well as the job. Buying the right kit once, rather than replacing unsuitable tools later, saves money and helps new starters build good habits from day one. Our bundles and kits are a sensible starting point.
Need a hand choosing parts for a job? Call the RACS team on 0161 775 1190, Monday to Friday, 9am–4pm.